Related Experiment Video
Updated: Jul 15, 2026

Quantitative In vitro Assay to Measure Neutrophil Adhesion to Activated Primary Human Microvascular Endothelial Cells under Static Conditions
Published on: August 23, 2013
Neutrophil adhesion to vascular prosthetic surfaces triggers nonapoptotic cell death
G S Nadzam1, C De La Cruz, R S Greco
1Department of Surgery, University of Medicine and Dentistry of New Jersey-Robert Wood Johnson Medical School, New Brunswick, New Jersey, USA.
Objective:
To test the hypothesis that neutrophil adhesion to expanded polytetrafluoroethylene (ePTFE) and Dacron triggers cell death.
Summary Background Data:
Vascular prosthetic infections are intransigent clinical dilemmas associated with excessive rates of death and complications. Impaired neutrophil function has been implicated in the infection of implanted cardiovascular devices. ePTFE and Dacron are potent neutrophil stimuli able to elicit activation responses such as reactive oxygen species production independent of exogenous/soluble agonists. Reactive oxygen species that are released into the medium when neutrophils are challenged by soluble agonists are known to cause self-destruction. The authors therefore sought to examine whether neutrophil adhesion to prosthetic graft materials decreases neutrophil viability by means of reactive oxygen species production.
Methods:
Neutrophils were adhered to surfaces for up to 6 hours. Cell viability was monitored with propidium iodide staining and lactate dehydrogenase release.
Results:
Within 6 hours of adhesion to ePTFE and Dacron, respectively, 59% +/- 11% and 44% +/- 5% (n = 7) of the neutrophils were stained by propidium iodide. Indistinguishable results were obtained with plasma-coated ePTFE and Dacron. In contrast, less than 2% of the neutrophils adherent to fibrinogen-, immunoglobin-, or fetal bovine serum-coated polystyrene surfaces for 6 hours were positive for propidium iodide. The increase in membrane permeability to propidium iodide was accompanied by a two- to threefold increase in lactate dehydrogenase release. Pretreatment of neutrophils with N-acetyl-L-cysteine, cytochalasin D, or cyclosporin A significantly reduced the number of propidium iodide-positive ePTFE and Dacron adherent neutrophils.
Conclusions:
Neutrophil adhesion to ePTFE and Dacron triggers a rapid nonapoptotic cell death. The effect of ePTFE and Dacron on neutrophil viability appears to be caused by reactive oxygen species production. The premature death of graft-adherent neutrophils provides a novel explanation of the defect in neutrophil bacterial killing associated with vascular prosthetic grafts.
Related Concept Videos
Inflammation
Phagocytosis of Apoptotic Cells
Normal cells contain receptors that prevent them from being recognized by phagocytes.
Autophagic Cell Death
Autophagy and Apoptosis
Autophagy can activate apoptosis. In normal conditions, the autophagy activating protein Beclin-1 and pro-apoptotic...
Necrosis
Morphological Manifestations of Necrosis
Necrotic cells show different types of morphological appearance depending on the type of tissue and infection. In coagulative necrosis, cells become anucleated and die, but their...
Intracellular Signaling Affects Focal Adhesions
Some...
Adherens Junctions
Adherens Junctions are Dynamic
The endothelial cells...