Safety, efficacy, and cost-effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: a
P Markowicz1, J D Ricard, D Dreyfuss
1Service de Réanimation Médicale, Hôpital Louis Mourier, Faculté Xavier Bichat, Université Paris VII, France.
Objective:
To determine whether three hydrophobic and hygroscopic heat and moisture exchangers (HMEs) retain their heating and humidifying properties (assessed by psychrometric measurements of absolute humidity, relative humidity, and tracheal temperature) for 48 hrs without any drop in their bacteriologic efficiency.
Design:
Prospective randomized clinical trial.
Patients:
Sixty-one consecutive unselected mechanically ventilated intensive care unit patients.
Interventions:
Patients were randomly allocated to one of the three HMEs studied (Hygrobac-Dar from Mallinckrodt, n = 21; Humid-Vent from Gibeck, n = 20; and Clear-Thermal from Intersurgical, n = 20).
Measurements And Main Results:
Hygrometric parameters were measured by psychrometry after 3, 24, and 48 hrs of use. Peak airway pressure was recorded every 6 hrs and averaged over 24 hrs. Bacterial colonization of both patients and circuits was studied. Patients in all three groups were similar in terms of age, indications for, and overall duration of mechanical ventilation. Tracheal tube occlusion never occurred. Hygrometric data included 371 measurements whereas bacteriologic data included >700 samples and cultures. The Hygrobac-Dar HMEs gave a significantly higher absolute humidity whatever the time of measurement (3, 24, or 48 hrs) than the other two HMEs (p < .001). The Clear-Thermal HMEs gave the poorest hygrometric parameters (p < .01); five of them were replaced prematurely (24 hrs) because the absolute humidity was <25 mg H2O/L. This did not occur for the other HMEs. Mean peak airway pressures were identical in the three groups. The bacterial colonizations of both patient and circuit were similar (and negligible for circuits) for all three groups.
Conclusion:
Some HMEs may be used safely for 48 hrs without change. However, this does not pertain to every brand of HME. Objective in vivo evaluation of their humidifying performances is decisive before extending their duration of use.
More Related Videos
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...