Resonant Coherent Anti-Stokes Raman Scattering Applied to Vapor Phase InI
1Institute for Laser and Plasmaphysics, Heinrich-Heine-University, Düsseldorf, Germany
Abstract:
The metal halide indium iodide (InI) is used as an important additive to mercury discharge lamps. The aim of this paper is to prepare resonant coherent anti-Stokes Raman scattering (RECARS) experiments for measuring concentration and temperature profiles of InI in commercially available metal halide lamps. The spectral positions of possible RECARS lines of InI (double and triple resonances) are calculated up to rotational quantum number J = 280 and vibrational quantum number v = 10. There is evidence for triple resonances leading to strong RECARS signals at J = 174 and J = 231. Dipole transition moments are calculated, which are important input data for the determination of the RECARS spectra. A degenerate-folded BOXCARS setup with a frequency-tripled Nd:YAG laser at 355 nm pumping two dye-laser systems oscillating near 411 nm is utilized to detect RECARS signals of the rovibronic transitions between X:(1)Sigma(+) and A:(3)Pi(0)(0(+)) states of InI. The laser output is attenuated to prevent saturation of the spectra. The tunable dye-laser systems have good beam-pointing stability and a small spectral width (<0.07 cm(-1)). Measured RECARS spectra from a pure InI vapor quartz cell at p = 120 Pa and T = 880 K are compared with theoretical data and good agreement is obtained with respect to the spectral position and RECARS intensity. The scatter signals are achieved with laser-pulse energies of less than 1 µJ. A collision-constant Gamma = 0.0025 cm(-1) describes the line broadening best. The experiments are also performed at a partial InI pressure of 1.12 kPa, a partial Hg pressure of 112 kPa, and a temperature of T = 1073 K and could be interpreted with a broadening constant Gamma = 0.23 cm(-1). Temperature measurements were performed between 900 and 1200 K with an accuracy of 7%. Copyright 2000 Academic Press.
More Related Videos
12:54Implementation of a Coherent Anti-Stokes Raman Scattering (CARS) System on a Ti:Sapphire and OPO Laser Based Standard Laser Scanning Microscope
Published on: July 17, 2016
09:46Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
Published on: April 28, 2022
Related Concept Videos
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
IR Absorption Frequency: Hybridization
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that stretch at a...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...