Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT01:25

Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

Calcium-Scoring CT ScanA calcium-scoring CT scan, also known as coronary artery calcium (CAC) scan, detects calcium deposits in the coronary arteries. This test assesses the risk of coronary artery disease (CAD), which can lead to cardiovascular events such as angina, heart failure, and sudden cardiac arrest.A calcium-scoring CT scan is generally recommended for individuals at intermediate risk of CAD without symptoms. It includes:Men aged 40-75 and women aged 50-75: Especially those with a...
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
Imaging Studies VII: Vascular Imaging01:19

Imaging Studies VII: Vascular Imaging

DefinitionRenal angiography, also known as renal arteriography, is an imaging technique used to obtain a comprehensive view of blood flow and the vascular structure of blood vessels in the kidneys and surrounding areas.PurposeRenal angiography detects blood vessel abnormalities in the kidneys, such as aneurysms, stenosis, thrombosis, vascular tumors, and renal artery stenosis. It evaluates kidney function and guides interventional treatments like angioplasty or stent placement.Pre-Procedure...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Wound of the Intestine-Recovery.

Chicago medical examiner·2023
Same author

Case of Vicarious Menstruation.

Atlanta medical and surgical journal·2022
Same author

An idiopathic facial dermatitis of Persian cats.

Veterinary dermatology·2021
Same author

Speeding publication.

Veterinary dermatology·2021
Same author

The use of compound 48/80 as a positive control in equine intradermal allergy testing.

Veterinary dermatology·2021
Same author

Follicular thyroid cancer: an update.

Current surgery·2000

Related Experiment Videos

Calculating Follow-up Rates.

Renquist1, Jeng, Mason

  • 1Department of Surgery, National Bariatric Surgery Registry, The University of Iowa College of Medicine, Iowa City, IA 52242-0178 USA.

Obesity Surgery
|November 1, 1992
PubMed
Summary
This summary is machine-generated.

Calculating follow-up rates after weight reduction surgery varies significantly. Standardizing these calculation methods is crucial for accurate comparisons of surgical outcomes.

Related Experiment Videos

Area of Science:

  • Bariatric surgery outcomes
  • Clinical trial methodology
  • Patient follow-up protocols

Background:

  • Follow-up rates are critical for assessing surgical treatment effectiveness, particularly in weight reduction surgery.
  • Current reporting of follow-up rates lacks standardization, hindering reliable comparisons between studies.
  • Understanding variations in follow-up rate calculations is essential for interpreting bariatric surgery outcomes.

Purpose of the Study:

  • To analyze and compare four distinct methods for calculating follow-up rates in patients undergoing surgical treatment for weight reduction.
  • To highlight the impact of different calculation methodologies on reported follow-up percentages.
  • To emphasize the need for a standardized approach to follow-up rate calculation in bariatric surgery research.

Main Methods:

  • Four methods were evaluated for calculating follow-up rates post-weight reduction surgery.
  • Method 1: Numerator based on any follow-up contact; Denominator based on primary operations.
  • Methods 2, 3, and 4: Varied definitions of follow-up contact (e.g., specific time points, adherence to guidelines like ASBS).

Main Results:

  • Follow-up rates varied substantially depending on the calculation method employed.
  • Method 1 yielded the highest rate (91.2%).
  • Rates decreased significantly when follow-up was defined by specific time intervals or adherence to guidelines (e.g., Method 4 rates ranged from 58.8% to 13.9% across different timeframes).

Conclusions:

  • The method used to calculate follow-up rates significantly influences reported outcomes in weight reduction surgery.
  • Discrepancies in calculation methodologies impede direct comparisons of surgical effectiveness across studies.
  • Standardization of follow-up rate calculation is imperative for advancing the field of bariatric surgery research and clinical practice.