H Abe1, A K Bhandari, R Lerman
1Division of Cardiology, The Hospital of the Good Samaritan, Los Angeles, CA, USA.
Abstract:
In 30 patients with drug refractory atrial fibrillation-flutter who underwent radiofrequency (RF) ablation of the atrioventricular (AV) junction, 23 were successfully ablated using the conventional right-sided approach (group A). Seven patients required a left-sided approach (group B) after multiple applications from the conventional right-sided approach failed to produce complete AV block. The amplitude of the His-bundle potential recorded at the ablation site differed significantly between the 2 groups (0.23+/-0.11 mV in group A vs 0.12+/-0.04 mV in group B; p<0.005). Also, the amplitude of the His-bundle potential recorded in the standard position across the tricuspid annulus differed significantly between the 2 groups (0.27+/-0.35 mV in group A vs 0.11+/-0.44 mV in group B; p<0.007). There was no significant difference in the amplitude of the ventricular potential between the 2 groups. The probability of successful ablation of the AV junction with a conventional right-sided approach was 6 out of 12 patients (50%) if the His amplitude was <0.12mV, and 17 out of 18 patients (94%) if the His amplitude was >0.12mV (p<0.005). Patients in group B had a mean of 20.5+/-13.0 failed right-sided RF applications (5-33 applications), but required a mean of only 2 subsequent RF applications for success on the left side (1-6 applications). The His-amplitude recorded from the left side using the same catheter was significantly greater than that on the corresponding right-side (0.22+/-0.09 mV on the left side vs 0.12+/-0.04 mV on the right side: p<0.05). Total mean fluoroscopic time was 62+/-12min for group B and 20+/-13min for group A patients. In patients that underwent RF ablation of the AV junction, a maximum His amplitude <0.12 mV predicted a success rate of approximately 50% in the present study. An early switch to a left-sided approach may avoid multiple RF applications and prolonged fluoroscopic time in patients with a low amplitude His-bundle potential.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Dysrhythmias IV: Characteristics of Bradyarrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias