An L-band crossed-loop (Bimodal) EPR resonator.

G A Rinard1, R W Quine, G R Eaton

  • 1Department of Engineering and Department of Chemistry and Biochemistry, University of Denver, Colorado 80208, USA.

Journal of Magnetic Resonance (San Diego, Calif. : 1997)
|April 28, 2000
PubMed
Summary

This study enhanced a crossed-loop resonator for Electron Paramagnetic Resonance (EPR) experiments, improving the filling factor and extending its frequency range. The design offers high mode isolation, reducing dead time in pulsed EPR.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Using rapid-scan EPR to improve the detection limit of quantitative EPR by more than one order of magnitude.

Journal of magnetic resonance (San Diego, Calif. : 1997)·2017
Same author

Electron Spin Relaxation Rates for High-Spin Fe(III) in Iron Transferrin Carbonate and Iron Transferrin Oxalate.

The journal of physical chemistry. B·2006
Same author

Phase memory relaxation times of spin labels in human carbonic anhydrase II: pulsed EPR to determine spin label location.

Biophysical chemistry·2002
Same author

Electron spin relaxation of triarylmethyl radicals in fluid solution.

Journal of magnetic resonance (San Diego, Calif. : 1997)·2001
Same author

Comparison of electron paramagnetic resonance methods to determine distances between spin labels on human carbonic anhydrase II.

Biophysical journal·2001
Same author

Interspin distances in spin-labeled metmyoglobin variants determined by saturation recovery EPR.

Biophysical journal·2000

Area of Science:

  • Physics
  • Spectroscopy
  • Resonator Technology

Background:

  • Electron Paramagnetic Resonance (EPR) spectroscopy is a powerful technique.
  • Traditional resonator designs can limit experimental efficiency.
  • Enhancing resonator performance is crucial for advancing EPR applications.

Purpose of the Study:

  • To improve the design of a crossed-loop resonator.
  • To increase the filling factor for better sensitivity.
  • To extend the operational frequency range of the resonator.

Main Methods:

  • Modification of a crossed-loop resonator design.
  • Extension of the resonator's frequency range from S-band to L-band.
  • Evaluation of mode isolation and filling factor.

Related Experiment Videos

Main Results:

  • The enhanced crossed-loop resonator design demonstrated an increased filling factor.
  • The resonator was successfully extended to operate in the L-band frequency range.
  • High isolation between the two operational modes was achieved.

Conclusions:

  • The enhanced crossed-loop resonator design offers improved performance for EPR.
  • High mode isolation leads to reduced dead time in pulsed EPR experiments.
  • This advancement is beneficial for various EPR applications requiring efficient operation.