Electromagnetic rewarming: the effect of CPA concentration and radio source frequency on uniformity and efficiency of
1University Engineering Department, Cambridge, CB2 1PZ, United Kingdom.
Abstract:
The relevant dielectric properties of a practical perfusate formula have been measured at radiofrequencies from 27 to 2954 MHz and temperatures from -75 to +25 degrees C. Both dimethyl sulfoxide and 2,3-butanediol were investigated as the cryoprotectant component at concentrations from 15 to 50%. The dielectric properties are considered in terms of new indices which characterize uniformity of heating, the power delivered and the efficiency of heating, and the avoidance of localized thermal runaway during very rapid heating. It becomes clear that a compromise must be accepted between nonuniformity of heating at the higher frequencies and inconveniently low power delivery at the lower frequencies. The choice of CPA and the concentration are found to be not very significant in these respects.
Related Concept Videos
Dual Nature of Electromagnetic (EM) Radiation
Wavelength is the distance between two consecutive peaks (the highest point) or troughs (the lowest point) in the wave. Frequency is the number of...
Electromagnetic Fields
However, the observation of Gauss's...
Standing Waves in a Cavity
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...