Related Experiment Video
Updated: Oct 16, 2026

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
A nonoccluding bag and closed scavenging system for the Jackson Rees modified T-piece breathing system
1Associate Professor and Senior Consultant Anasthetist; Consultant Anasthetist, National University Hospital, 5 Lower Kent Ridge Road, Singapore 119074.
Abstract:
We used the inner tube and its 22-mm connector from the patient end of a Bain breathing system to splint the double-ended bag of the Jackson Rees modification of the Ayre's T-piece breathing system. A paediatric airway pressure-limiting valve was connected to the distal end of the tube for closed scavenging. The resistance of the modified bags was similar to that of unmodified bags at gas flows below 11 l.min-1. The valve offered no resistance to gas flows below 5 l.min-1. During its use in 30 paediatric patients, analysis of carbon dioxide from inside the bag and from the expiratory port confirmed no loss of deadspace gas by preferential flow bypassing the bag into the scavenging system.
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...