Related Experiment Video
Updated: Oct 16, 2026

Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
Effects of dialyzer reuse on the permeability of low-flux membranes
J P Matos1, M B André, S M Rembold
1Department of Internal Medicine, Division of Nephrology, and Department of Pathology, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil.
Abstract:
Little attention has been given to the effects of reuse on the permeability of low-flux membranes, especially regarding middle molecules. We studied two different types of low-flux membranes at reuses 0, 6, and 12 in five patients undergoing hemodialysis with the following combinations of membrane and sterilant: cellulose diacetate membrane and formaldehyde, polysulfone membrane and formaldehyde, cellulose diacetate membrane and peracetic acid, and polysulfone and peracetic acid. The permeability of the membranes was assessed through the hydraulic ultrafiltration coefficient (K(UF)), sieving coefficient for beta(2)-microglobulin (B2M), and vitamin B(12) and albumin concentrations in ultrafiltrate. After 12 reuses, total cell volume (TCV) tended to be reduced in both cellulose diacetate and polysulfone dialyzers irrespective of the sterilant used, but significance was only found for the first set of dialyzers. Cellulose diacetate dialyzers reprocessed with either formaldehyde or peracetic acid showed an important reduction in K(UF) (31% [P < 0.05] and 23% [P < 0.05], respectively). A significant elevation in K(UF) was found in polysulfone membranes reprocessed with peracetic acid (41%; P < 0.05), but no alterations in K(UF) were found in polysulfone membranes reprocessed with formaldehyde. Cellulose diacetate membranes were intrinsically more permeable to B2M than polysulfone membranes (sieving coefficient, 6. 85 +/- 2.53 versus 0.04 +/- 0.02 x 10(-2); P < 0.001), which was not modified by any of the sterilants. Vitamin B(12) levels in ultrafiltrate decreased to an undetectable level in four of five samples collected after 12 reuses in polysulfone membranes reprocessed with peracetic acid (90 +/- 71 to 3 +/- 8 pg/mL; P < 0. 05 versus reuse 0). Albumin leakage occurred in two of five samples after the 12th reuse, but only in polysulfone membranes reprocessed with peracetic acid. Our findings suggest that reuse of low-flux polysulfone dialyzers reprocessed with peracetic acid is associated with structural damage of the membrane and a reduced permeability to middle molecules.
Related Concept Videos
Dialysis
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Peritoneal Dialysis I: Introduction and Procedure
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Hemodialysis I: Introduction
Hemodialysis II: Procedure and Complications