M Henry-Feugeas1, I Alkilic-Genauzeau, N Aymé
1Service de Radiologie, Hôpital Bichat Claude Bernard, Laboratoire d'Imagerie Médicale Paris-Nord JE2156, 46, rue Henri Huchard, 75877 Paris Cedex 18, France.
Purpose:
To assess the intraobserver variability of echoDoppler sonographic measurement of various carotid arteries parameters.
Materials And Methods:
Repeated bilateral carotid examinations were performed in ten healthy subjects, using three color-coded duplex ultrasound systems (two Acuson 128 XP, one ATL HDI 3000) and different linear probes. Each examination included two successive sets of measurements.
Results:
The resistive index values decreased from the proximal common carotid artery to the distal common carotid artery (p <10(-7)). According to the set of measurements and to the equipments considered, the range of mean absolute differences of the systolic peak velocity (PSV), the end diastolic velocity (EDV) values, the ICA/CCA PSV and PSV/EDV velocity ratios and the resistive index (RI) values were 8-16cm/s, 3-6cm/s, 0.08-0,15 and 0. 16-0.26, and 0.02-0.06 respectively. Standard deviations of the proportional differences of the RI and PSV measurements averaged respectively 6% and 15% and were always reduced by repeating the measurements. The use of similar ultrasound machines was not associated with a reduced variability.
Conclusion:
The substantial variability of Doppler measurements in carotid arteries, even with the use of the same operator and similar machines could be reduced using "angle independent" parameters.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation