Related Experiment Video
Updated: Jul 29, 2026

A Study of the Complexation of Mercury(II) with Dicysteinyl Tetrapeptides by Electrospray Ionization Mass Spectrometry
Published on: January 8, 2016
Comparison of different derivatization approaches for mercury speciation in biological tissues by gas
R García Fernández1, M Montes Bayón, J I García Alonso
1Department of Physical and Analytical Chemistry, University of Oviedo, C/Julián Clavería 8, 33006 Oviedo, Spain.
Abstract:
A novel interface design for coupling gas chromatography and inductively coupled plasma mass spectrometry (GC/ICP-MS) was used to perform mercury speciation in biological tissues. Three derivatization approaches were optimized and compared for this purpose: anhydrous butylation using a Grignard reagent, aqueous ethylation by means of NaEt(4)B and aqueous propylation with NaPr(4)B. The last reagent was synthesized in the laboratory as it is not commercially available. Detection limits obtained by GC/ICP-MS ranged between 100 and 200 fg (as absolute mass) for methylmercury and between 500 and 600 fg for inorganic mercury using a 1 microl injection. Quantification of methyl- and inorganic mercury was carried out by resorting to aqueous calibration, using ethylmercury as internal standard for both propylation and butylation derivatization techniques. For ethylation procedures, a methylpropylmercury solution was used as internal standard. The absence of transmethylation during sample preparation was checked using a 97% enriched (202)Hg inorganic standard. The accuracy of the three derivatization approaches was evaluated by the analysis of the certified reference material DOLT-2 (dogfish liver) from the National Research Council of Canada and certified for methylmercury, with satisfactory results.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
04:19An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Types of Detectors