Related Experiment Video
Updated: Jun 27, 2026
![Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F50301.jpg&w=3840&q=50)
Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
Published on: March 23, 2013
A valid, accurate, office based non-radioactive test for gastric emptying of solids
J S Lee1, M Camilleri, A R Zinsmeister
1Gastroenterology Research Unit, Mayo Clinic and Mayo Foundation, Rochester, Minnesota, USA.
Background:
Current breath tests for measurement of gastric emptying of solids are expensive, possibly inaccurate, and require cumbersome calculations.
Aims:
We wished to validate a simplified solid gastric emptying test using a [(13)C]Spirulina platensis breath test for accurate results relative to scintigraphy.
Subjects:
Thirty healthy volunteers.
Methods:
We measured gastric emptying of egg containing [(13)C]S platensis and (99m)Tc sulphur colloid by breath (13)CO(2) and scintigraphy over six hours. A generalised linear regression model was used to predict t(1/2) and t(LAG) by scintigraphy from breath (13)CO(2) data. The model was cross validated and normative data calculated for a prepacked [(13)C]meal.
Results:
Regression models using all breath data over six hours, for the first three hours, and for samples at 75, 90, and 180 minutes ("reduced model") predicted t(1/2) and t(LAG) values similar to scintigraphy (t(LAG) 43 (SD 12) min; t(1/2) 100 (20) min). Standard deviations of differences in t(1/2) and t(LAG) between scintigraphy and the "reduced model" were both 10 minutes. Gastric t(1/2) for the prepacked [(13)C]meal was 91 (15) min (10-90% range: 74-118).
Conclusion:
The [(13)C]S platensis breath test and a simple formula using breath (13)CO(2) at baseline, 90, and 180 minutes measured gastric emptying t(1/2) for solids with results that were comparable with scintigraphy.
Related Concept Videos
Gastric Emptying
Serum Laboratory Studies, Stool Test, Breath Test
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...