Related Experiment Video
Updated: Aug 19, 2026

Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
Moisture uptake and its influence on pressurized metered-dose inhalers
1Division of Pharmaceutics, College of Pharmacy, University of Texas at Austin, 78712, USA. williro@mail.utexas.edu
Abstract:
The objective of this study was to investigate moisture ingress into pressurized metered dose inhalers (pMDIs) containing hydrofluoroalkane (HFA) propellants and the consequences of this ingress. Moisture ingress into the pMDIs containing tetrafluoroethane (HFA 134a) or heptafluoropropane (HFA 227) was evaluated and modeled. The influence of water level in pMDIs on the stability of pMDIs containing triamicinolone acetonide (TAA) and beclomethasone dipropionate (BDP) in terms of particle growth, fine particle fraction, and drug solubility in the propellant system was evaluated using scanning electron microscopy, particle size analysis, single-stage impaction, and HPLC. The water level in HFA-containing pMDIs increased during storage and the process obeyed a diffusion model. HFA 134a had a greater tendency to take up moisture from the environment than did HFA 227. Unlike TAA, the propensity for particle growth of the suspended BDP in HFA propellants was significantly depressed by the increase in water level in the pMDIs. As a result, the fine particle fraction of the emitted BDP aerosols significantly increased as the water level in the HFA propellant was increased. Moisture ingress into pMDIs containing HFAs occurred during storage. The influence of the increased water level in pMDIs on the physical stability of the pMDI formulation and the dose delivery performance was a function of the composition of the internal lining of the container, the type of drug and propellant, and storage temperature.
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Inhaled Medications
Factors Influencing Drug Absorption: Pharmaceutical Parameters
Moisture Content and Bulking of Aggregate
When aggregates are exposed to rain or sit in stockpiles, they absorb moisture, which must be...

