Related Experiment Video
Updated: Jul 24, 2026

Testing Tactile Masking between the Forearms
Published on: February 10, 2016
Comparing contrast-modulated and luminance-modulated masking: effects of spatial frequency and phase
A Willis1, H S Smallman, J M Harris
1Department of Psychology, University of Newcastle, Newcastle upon Tyne, UK. a.willis@napier.ac.uk
Abstract:
The masking of a sinusoidal test grating by contrast-modulated (CM) gratings could, in principle, be attributable to the presence of a distortion product, injected into the stimulus during some nonlinear transformation at an early level of visual processing (e.g. Nachmias, 1989 Vision Research 29 137-142). If so, CM gratings and luminance-modulated (LM) gratings of similar effective contrast and spatial frequency should mask the detection of sinusoids in a similar fashion. We compared the effects of masking by 1 cycle deg-1 CM gratings [both simple beats (8 + 9 cycles deg-1) and amplitude-modulated gratings (8 + 9 + 10 cycles deg-1)], with those of masking by 1 cycle deg-1 LM gratings of low contrast. We found that: (i) CM and low-contrast LM grating masks yielded similar spatial-frequency tuning functions around the modulation frequency of 1 cycle deg-1; (ii) low-contrast LM gratings masked the detection of test sinusoids in a highly phase-dependent fashion, while masking by CM gratings did not vary systematically with relative spatial phase. The results suggest that masking produced by CM gratings cannot simply be explained by the presence of a distortion product at the beat or modulation frequency.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...

