Accretion of primitive planetesimals: Hf-W isotopic evidence from enstatite chondrites

Lee1, Halliday

  • 1Department of Geological Sciences, University of Michigan, Ann Arbor, MI 48109-1063, USA. Institute for Isotope Geology and Mineral Resources, Department of Earth Sciences, ETH Zurich, CH-8092, Zurich, Switzerland.

Science (New York, N.Y.)
|June 2, 2000
PubMed

Related Concept Videos

Conditions on Early Earth02:06

Conditions on Early Earth

Around 4 billion years ago, oceans began to condense on earth while volcanic eruptions released nitrogen, carbon dioxide, methane, ammonia, and hydrogen into the primordial atmosphere. However, organisms with the characteristics of life were not initially present on earth. Scientists have used experimentation to determine how organisms evolved that could grow, reproduce, and maintain an internal environment.
Atomic Mass01:52

Atomic Mass

Atoms — and the protons, neutrons, and electrons that compose them — are extremely small. For example, a carbon atom weighs less than 2 × 10−23 g. When describing the properties of tiny objects such as atoms, we use appropriately small units of measure, such as the atomic mass unit (amu). The amu was originally defined based on hydrogen, the lightest element, then later in terms of oxygen. Since 1961, it has been defined with regard to the most abundant isotope of carbon, atoms of which are...
Nuclear Stability03:18

Nuclear Stability

Protons and neutrons, collectively called nucleons, are packed together tightly in a nucleus. With a radius of about 10−15 meters, a nucleus is quite small compared to the radius of the entire atom, which is about 10−10 meters. Nuclei are extremely dense compared to bulk matter, averaging 1.8 × 1014 grams per cubic centimeter. If the earth’s density were equal to the average nuclear density, the earth’s radius would be only about 200 meters.
To hold positively charged protons together in the...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...