Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
High temporal resolution for multislice helical computed tomography
1Medical Systems Research and Development Center, Medical Systems Company, Toshiba Corporation, Tochigi, Japan. ktaguchi@mel.nasu.toshiba.co.jp
Abstract:
Multislice helical computed tomography (CT) substantially reduces scanning time. However, the temporal resolution of individual images is still insufficient for imaging rapidly moving organs such as the heart and adjacent pulmonary vessels. It may, in some cases, be worse than with current single-slice helical CT. The purpose of this study is to describe a novel image reconstruction algorithm to improve temporal resolution in multislice helical CT, and to evaluate its performance against existing algorithms. The proposed image reconstruction algorithm uses helical interpolation followed by data weighting based on the acquisition time. The temporal resolution, the longitudinal (z-axis) spatial resolution, the image noise, and the in-plane image artifacts created by a moving phantom were compared with those from the basic multislice helical reconstruction (helical filter interpolation, HFI) algorithm and the basic single-slice helical reconstruction algorithm (180 degrees linear interpolation, 180LI) using computer simulations. Computer simulation results were verified with CT examinations of the heart and lung vasculature using a 0.5 second multislice scanner. The temporal resolution of HFI algorithm varies from 0.28 and 0.86 s, depending on helical pitch. The proposed method improves the resolution to a constant value of 0.29 s, independent of pitch, allowing moving objects to be imaged with reduced blurring or motion artifacts. The spatial (z) resolution was slightly worse than with the HFI algorithm; the image noise was worse than with the HFI algorithm but was comparable to axial (step-and-shoot) CT. The proposed method provided sharp images of the moving objects, portraying the anatomy accurately. The proposed algorithm for multislice helical CT allowed us to obtain CT images with high temporal resolution. It may improve the image quality of clinical cardiac, lung, and vascular CT imaging.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...