Related Experiment Video
Updated: Aug 19, 2026

Synthesis of Soft Polysiloxane-urea Elastomers for Intraocular Lens Application
Published on: March 8, 2019
Posterior capsular opacification with hydrogel, polymethylmethacrylate, and silicone intraocular lenses: two-year
E J Hollick1, D J Spalton, P G Ursell
1Department of Ophthalmology, St Thomas' Hospital, London, England, UK.
Purpose:
To compare the visual outcome, percentage of posterior capsular opacification, and laser capsulotomy rates with polymethylmethacrylate, silicone, and hydrogel intraocular lens implants at 1 and 2 years postoperatively.
Methods:
Ninety-three eyes of 93 patients were randomized to receive a polymethylmethacrylate, silicone, or hydrogel intraocular lens implant. A standardized surgical protocol was followed by a single surgeon using phacoemulsification with capsulorhexis; any patients with surgical complications were excluded, and all patients received standardized medication and follow-up. Patients were examined at days 1 and 7, months 1, 3, and 6, and years 1 and 2 after surgery. At each assessment, best-corrected logMAR visual acuity and Pelli-Robson contrast sensitivity were measured. Posterior capsular opacification was objectively assessed by digital retroillumination imaging with the use of a dedicated software program and calculated as the percentage area of opacified capsule. Laser capsulotomy was performed if the eye had lost 2 lines of visual acuity with a clinically opaque capsule.
Results:
At 2 years postoperatively, the mean percentage area of posterior capsular opacification for hydrogel lenses was 63%; for polymethylmethacrylate, 46%; and for silicone, 17%. Hydrogel intraocular lenses were associated with 17% more posterior capsule opacification than were polymethylmethacrylate lenses (95% confidence interval, 1-33; P =. 037) and 45% more than were silicone lenses (95% confidence interval, 33-58; P <.0001) at 2 years. Polymethylmethacrylate lenses had 28% more posterior capsule opacification than silicone lenses (95% confidence interval, 13-43; P <.0001) at 2 years. Twenty-eight percent of patients with hydrogel intraocular lenses required an Nd:YAG laser posterior capsulotomy at 2 years, compared with 14% with polymethylmethacrylate, whereas no patients with silicone lenses needed a capsulotomy (P =.014). Visual acuity was not significantly different among the three groups, but patients with silicone intraocular lenses had significantly better contrast sensitivity than those with hydrogel lenses (P =.046).
Conclusions:
Intraocular lenses made of this specific hydrogel were associated with a significantly higher degree of posterior capsular opacification and more laser capsulotomies than polymethylmethacrylate and silicone intraocular lenses.
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment

