Related Experiment Videos
In vivo visualization of hemodialysis-induced alterations in leukocyte-endothelial interactions
M E Van Teijlingen1, P Borgdorff, M H Van Wijhe
1Laboratory for Physiology and Department of Nephrology, Institute for Cardiovascular Research (ICaR-VU), Vrije Universiteit, Amsterdam, The Netherlands. me.van_teijlingen.physiol@med.vu.nl
Background:
The aim of this study was to develop a model for hemodialysis (HD) in small animals using conventional dialysis equipment that would allow the intravital microscopic observation of leukocyte-endothelial interactions in vivo.
Methods:
Cuprophan dialyzers were adapted to obtain a similar ratio of membrane area to blood volume as in clinical HD. A silicone ring was inserted into the dialyzer's inlet to limit the number of blood-perfused capillaries. Rabbits were dialyzed for one hour without a dialysate flow.
Results:
Extracorporeal circulation with the cuprophan dialyzer resulted in a transient leukopenia and complement activation. At the nadir of leukopenia, leukocytes that rolled along the venular wall were scarcely observed, whereas rolling was abundant (54 +/- 9 per min) prior to extracorporeal circulation. The adhesion of leukocytes to the vascular endothelium was not induced. After 60 minutes, rolling of leukocytes was still reduced by 73 +/- 5.5%, despite the full recovery of circulating leukocyte counts. Extracorporeal circulation without a dialyzer also tended to reduce leukocyte rolling, although systemic leukocyte counts were not affected.
Conclusions:
The use of adapted conventional cuprophan hemodialyzers in rabbits yielded a transient leukopenia similar to that in clinical HD. Using intravital microscopy, we demonstrated impairment of leukocyte-endothelial interactions. In addition, our data indicate that tissues, in which leukocytes can roll and adhere, are not automatically sites of leukocyte sequestration during HD-induced leukopenia.