Related Experiment Video
Updated: Oct 16, 2026

Solvent Bonding for Fabrication of PMMA and COP Microfluidic Devices
Published on: January 17, 2017
Bonding amalgam to a resin-modified glass-ionomer base
1Operative Section-Restorative Department, Southern Illinois University School of Dental Medicine, Alton 62002, USA. mbelche@siue.edu
Purpose:
To determine which surface treatment of a resin-modified glass-ionomer (RMGI) will result in optimal bond strength to amalgam when used with an amalgam adhesive.
Materials And Methods:
Fifty discs of Fuji II LC (4 mm thick) were cured in acrylic testing holders and randomly divided into 5 groups of 10 each. The surface of the glass-ionomer was treated in 1 of 5 ways: (1) no treatment (control) (2) no etch, Amalgambond (AB) primer and AB adhesive (3) citric acid etch, AB primer, and AB adhesive (per manufacturer's instructions) (4) 37.5% phosphoric acid etch, AB primer and AB adhesive, and (5) microetch, 37.5% phosphoric acid etch, AB primer and AB adhesive. Amalgam was condensed onto the treated RMGI surface. Samples were stored in water at 37 degrees C and tested at 24 hours for shear bond strength. The data was analyzed statistically by ANOVA followed by Scheffé post hoc tests for significance. Glass-ionomer discs were also treated as described in each group, sputter-coated and examined using a scanning electron microscope.
Results:
No significant improvement in bond strengths to amalgam was observed with any of the treatments of the RMGI surface. Amalgambond significantly increased the bond strength of the amalgam to the RMGI.
Related Concept Videos
Bonding and Strength of Aggregate
Bonding in Metals