Determinants of ceftriaxone clearance by continuous venovenous hemofiltration and hemodialysis
G R Matzke1, R F Frye, M S Joy
1School of Medicine, University of Pittsburgh, Pennsylvania 15261, USA.
Study Objective:
To guide individual ceftriaxone dosages in patients receiving continuous renal replacement therapy.
Design:
Prospective, outpatient study.
Setting:
University-affiliated general clinical research center.
Patients:
Eight patients receiving hemodialysis.
Intervention:
We performed controlled clearance studies with three hemofilters: an acrylonitrile copolymer 0.6 m2 (AN69), polymethylmethacrylate 2.1 m2 (PMMA), and polysulfone 0.65 m2 (PS).
Measurements And Main Results:
Subjects received ceftriaxone 1000 mg intravenously before the start of a clearance study. The concentration of ceftriaxone in multiple plasma and dialysate-ultrafiltrate samples was determined by high-performance liquid chromatography. The diffusional clearances (Cl(diffusion)) and sieving coefficients (SC) of ceftriaxone, urea, and creatinine were compared by a mixed-model repeated-measures analysis of variance with filter and blood, dialysate inflow, or ultrafiltration rate as the main effect and patient as a random effect. The fraction of ceftriaxone bound to plasma proteins was 43 +/- 15% (range 13-92%). Concentration dependence was evident in all three groups. The fraction unbound to plasma proteins (f(up)) at the time that SCs were determined was significantly lower in the PS group (0.16 +/- 0.07) than the AN69 group (0.30 +/- 0.17, p<0.01), but similar to that in the PMMA group (0.27 +/- 0.12). Despite the higher f(up), the SC of unbound ceftriaxone with the AN69 filter (0.48 +/- 0.13) was significantly lower than values for the PMMA (0.86 +/- 0.33) and PS (0.82 +/- 0.22) groups (p<0.05). Continuous venovenous hemofiltration clearance of urea and unbound ceftriaxone increased significantly only for the PMMA (p=0.006) and PS (p=0.015) filters when the ultrafiltration rate was increased. Significant linear relationships (p<0.0001) were observed between Cl(diffusion) of unbound ceftriaxone and clearance of urea for all three filters: AN69 slope = 0.57, PMMA slope = 0.90, and PS slope = 1.02. The slope of this relationship for the AN69 filter was significantly lower than for the other two filters.
Conclusion:
Ceftriaxone clearance was significantly increased and membrane dependent during continuous venovenous hemofiltration and continuous venovenous hemodialysis. Thus individual ceftriaxone dosages for patients receiving continuous renal replacement therapies should incorporate extracorporeal clearance.
Related Concept Videos
Factors Affecting Renal Clearance: Drug's Physicochemical Properties and Plasma Levels
One important factor is the drug's molecular size. The kidneys readily excrete smaller molecules below 300 Daltons (Da). On the other hand, molecules weighing between 300 and 500 Da are excreted through both urine and bile. Larger molecules above 500 Da tend to be excreted less...
Factors Affecting Renal Clearance: Drug Distribution and Drug Interactions
One important factor is the relationship between renal clearance and the apparent volume of distribution. Renal clearance tends to be inversely proportional to the apparent volume of distribution. Drugs with an extensive distribution volume or those...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Continuous Renal Replacement Therapy