Related Experiment Video
Updated: Oct 15, 2026

Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Reliability of torque measurements during passive isokinetic knee movements in healthy subjects
G Nuyens1, W de Weerdt, A Spaepen
1Department of Rehabilitation Sciences, University of Leuven, Belgium. Lieve.Nuyens@flok.kuleuven.ac.be
Abstract:
In the literature, few data are available about the reliability of torque measured during passive isokinetic knee movements. This study investigated the consistency of torque measurements during passive knee movements at 60, 180 and 300 degrees/second in 30 healthy subjects. Intraclass correlation values ranged between 0.78 and 0.92 when the results of two consecutive tests were compared. When retests were performed after repositioning the subjects, intraclass correlation values ranged between 0.43 and 0.87. These findings indicate the necessity for meticulous standardization of the test situation. Series of 10 consecutive movements, specifically repetitions of knee flexion at 180 and 300 degrees/second, indicated that torque measurements during the first two movements were less stable than those following. A concurrent change in electromyographic activity in the rectus femoris muscle suggested that these torque variations resulted from habituation of the stretch reflex.
More Related Videos
07:45Quantifying Recovery After Anterior Cruciate Ligament Reconstruction Using the Torque- Velocity Relationship
Published on: July 24, 2026
12:59Improving Strength, Power, Muscle Aerobic Capacity, and Glucose Tolerance through Short-term Progressive Strength Training Among Elderly People
Published on: July 5, 2017