Time to recover from atrial hormonal, mechanical, and electrical dysfunction after successful electrical
M Nishino1, S Hoshida, J Tanouchi
1Division of Cardiology, Osaka Rosai Hospital, Sakai, Japan. mnishino@orh.go.jp
Abstract:
Although transient atrial dysfunction has been reported after electrical cardioversion of atrial fibrillation (AF), the difference in the time to recover from the atrial hormonal, mechanical, and electrical dysfunction has not been described. Thus, we evaluated the time course of recovery from atrial hormonal, mechanical, and electrical dysfunction after cardioversion in patients with nonvalvular AF. We attempted electrical cardioversion in 87 consecutive patients with nonvalvular AF that had persisted for > or =6 months, and in 24 patients (28%) with maintained sinus rhythm for > or =6 months. To evaluate atrial hormonal, mechanical, and electrical dysfunction in these 24 patients, we measured plasma concentration of atrial natriuretic peptide, the atrial peak velocity in transmitral flow, and the ratio of peak systolic-to-diastolic pulmonary venous flow (S/D ratio) using echocardiography, and the duration and the root mean voltage for the terminal 20 ms (LP20) of the filtered P wave using P-wave signal-averaged electrocardiography. Atrial natriuretic peptide rapidly returned to baseline within 1 day after cardioversion, and maintained these levels for 6 months. Atrial peak velocity in transmitral flow and S/D ratio were significantly increased at 2 weeks, and continued to increase until 1 month, and then reached a plateau. The duration and LP20 began to recover only 6 months after cardioversion. One to 3 years after conversion, the duration and LP20 had nearly reached a plateau, but the latter value remained below normal. In patients with nonvalvular AF of prolonged duration, recovery from atrial electrical dysfunction after sinus conversion took much longer than that from either atrial hormonal or mechanical dysfunction.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias VI: Management of Dysrhythmias
Cardiopulmonary Resuscitation IV: Pharmacological Management