Related Experiment Video
Updated: Jul 9, 2026

Cardiac Stress Test Induced by Dobutamine and Monitored by Cardiac Catheterization in Mice
Published on: February 10, 2013
Cardiac hypertrophy is not a required compensatory response to short-term pressure overload
J A Hill1, M Karimi, W Kutschke
1Division of Cardiovascular Diseases, Department of Internal Medicine, Department of Veterans Affairs, University of Iowa College of Medicine, Iowa City 52242-1081, USA. joseph-hill@uiowa.edu
Background:
Cardiac hypertrophy is considered a necessary compensatory response to sustained elevations of left ventricular (LV) wall stress.
Methods And Results:
To test this, we inhibited calcineurin with cyclosporine (CsA) in the setting of surgically induced pressure overload in mice and examined in vivo parameters of ventricular volume and function using echocardiography. Normalized heart mass increased 45% by 5 weeks after thoracic aortic banding (TAB; heart weight/body weight, 8.3+/-0.9 mg/g [mean+/-SEM] versus 5. 7+/-0.1 mg/g unbanded, P<0.05). Similar increases were documented in the cell-surface area of isolated LV myocytes. In mice subjected to TAB+CsA treatment, we observed complete inhibition of hypertrophy (heart weight/body weight, 5.2+/-0.3 mg/g at 5 weeks) and myocyte surface area (endocardial and epicardial fractions). The mice tolerated abolition of hypertrophy with no signs of cardiovascular compromise, and 5-week mortality was not different from that of banded mice injected with vehicle (TAB+Veh). Despite abolition of hypertrophy by CsA (LV mass by echo, 83+/-5 mg versus 83+/-2 mg unbanded), chamber size (end-diastolic volume, 33+/-6 microL versus 37+/-1 microL unbanded), and systolic ejection performance (ejection fraction, 97+/-2% versus 97+/-1% unbanded) were normal. LV mass differed significantly in TAB+Veh animals (103+/-5 mg, P<0.05), but chamber volume (end-diastolic volume, 44+/-6 microL), ejection fraction (92+/-2%), and transstenotic pressure gradients (70+/-14 mm Hg in TAB+Veh versus 77+/-11 mm Hg in TAB+CsA) were not different.
Conclusions:
In this experimental setting, calcineurin blockade with CsA prevented LV hypertrophy due to pressure overload. TAB mice treated with CsA maintain normal LV size and systolic function.
Related Concept Videos
Heart Failure Drugs: β-Blockers
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Heart Failure II: Pathophysiology
Heart Failure V: Medical Management

