Related Experiment Videos
Comparison of three facebow/semi-adjustable articulator systems for planning orthognathic surgery
1Orthodontic Department, Liverpool University Dental Hospital, Liverpool, UK.
Abstract:
Our aim was to measure the steepness of the occlusal plane produced by three different semi-adjustable articulators: the Dentatus Type ARL, Denar MkII, and the Whipmix Quickmount 8800, and to assess the influence of possible systematic errors in positioning of study casts on articulators that are used to plan orthognathic surgery. Twenty patients (10 skeletal class II, and 10 skeletal class III) who were having pre-surgical orthodontics at Liverpool University Dental Hospital were studied. The measurement of the steepness of the occlusal plane was taken as the angle between the facebow bite-fork and the horizontal arm of the articulator. This was compared with the angle of the maxillary occlusal plane to the Frankfort plane as measured on lateral cephalometry (the gold standard). The Whipmix was closest to the gold standard as it flattened the occlusal plane by only 2 degrees (P<0.05). The results of the Denar and Dentatus differed significantly from those of the cephalogram as they flattened the occlusal plane by 5 degrees and 6. 5 degrees (P<0.01), respectively. Clinicians are encouraged to verify the steepness of the occlusal plane on mounted study casts before the technician makes the model.