Related Experiment Video
Updated: Oct 15, 2026

Probe-based Confocal Laser Endomicroscopy of the Urinary Tract: The Technique
Published on: January 10, 2013
Inter-observer variation in delineation of bladder and rectum contours for brachytherapy of cervical cancer
A E Saarnak1, M Boersma, B N van Bunningen
1Department of Radiotherapy, The Netherlands Cancer Institute/Antoni van Leeuwenhoek Huis, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands.
Background And Purpose:
In 3D treatment planning of low dose rate brachytherapy of cervical carcinoma the dose in bladder and rectum can be estimated from dose-volume histograms (DVHs). In this study, the influence of inter-observer variation in delineation of bladder and rectum on DVHs and dose at specific bladder and rectum points was investigated.
Materials And Methods:
Three observers delineated bladder and rectum on axial CT images of ten patients. The highest minimum dose in bladder and rectum was determined for, respectively, 2 cm(3) (D(2)) and 5 cm(3) (D(5)), as well as the dose at specific points placed on the bladder and rectum wall.
Results:
The inter-observer variation in D(2) was 10% (1 average relative SD) in bladder and 11% (1 SD) in rectum. In D(5) the variation was 8% (1 SD) in bladder and 11% in rectum. The variation in the bladder point was 13% (1 SD) and in the rectum point 11% (1 SD). Differences in delineation among the observers were caused by unclear organ boundaries on the CT images.
Conclusions:
Taking the inter-observer variation caused by delineation differences into account, dose in bladder and rectum can be determined within an accuracy of about 10% (1 SD).