Related Experiment Video
Updated: Oct 15, 2026

Tachycardia-Induced Cardiomyopathy As a Chronic Heart Failure Model in Swine
Published on: February 17, 2018
A comparison of bolus versus continuous cardiac output in an experimental model of heart failure
P O'Malley1, B Smith, R Hamlin
1Department of Veterinary Biosciences, College of Veterinary Medicine, Ohio State University, Columbus, USA.
Objective:
The majority of studies examining cardiac output measurement have been done in physiologically stable models with low thermal background noise. Research comparing continuous cardiac output (CCO) with bolus thermodilution cardiac output (COTD) measures in human and animal models have reported high correlations, negligible bias, but large limits of agreement. The purpose of this project was to compare CCO with COTD measures in an experimental model of heart failure where the cardiac output values were low and the range was narrow.
Design:
A one-group experimental design with preintervention control measures and repeated CCO and COTD measures across nine time points.
Setting:
Cardiovascular research laboratory.
Subjects:
Thirty dogs.
Measures And Main Results:
Univariate and multivariate versions of repeated-measures analysis were used to assess the influences of temperature, weight, and stage of the experimental protocol on CCO, COTD, and the differences between them. The two measures CCO and COTD were assessed for agreement by using methods proposed by Bland and Altman. Two hundred and fifty pairs of measurements were obtained during sinus rhythm. The range for COTD measures was 0.5-4.67 L/min and for CCO measures 1.0-5.40 L/min. Of the 250 cardiac outputs estimated by the continuous method, 73.4% of the values were within +/-15% of that estimated by the repetitive, single thermodilution method. The mean bias for the entire protocol was 0.01 (SD = 0.51) with a range of 4.33 L/min.
Conclusion:
Agreement between the two measures may be the function of biological variability, responses to anesthesia, and technique. Bland and Altman evaluation demonstrated low bias and precision and similar levels of agreement when compared with previous studies in an experimental model where the cardiac output was low and the range was narrow.
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Pathophysiology of Heart Failure
Heart Failure I: Introduction