Related Experiment Video
Updated: Sep 1, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
High-performance liquid chromatographic optimization study for the separation of natural and synthetic anabolic
R Gonzalo-Lumbreras1, R Izquierdo-Hornillos
1Departamento de Química Analítica, Facultad de Química, Universidad Complutense de Madrid, Spain.
Abstract:
An HPLC separation of a complex mixture containing 14 androgenic anabolic steroids (natural and synthetic) for screening purposes has been carried out. The applied optimization method involved the use of binary, ternary and quaternary mobile phases containing acetonitrile, methanol or tetrahydrofuran as organic modifiers. The effect of different reversed-phase packings and temperature on the separation using acetonitrile as organic modifier was studied. The optimum separation was achieved by using a water-acetonitrile (55:45, v:v) mobile phase and a Hypersil ODS (250 mm x 4.6 mm) 5 microm column (30 degrees C) in about 38 min, allowing the separation of 14 out of 14 compounds tested (when danazol is excluded, 13 out of 14 were separated in 23 min). Calibration graphs were obtained using bolasterone, methyltestosterone and canrenone as internal standards. Detection limits were in the range 0.012-0.11 microg ml(-1). The optimized separation was applied for monitoring the norethindrone acetate hydrolysis from tablets and to the analysis, after liquid-liquid extraction, of urine samples spiked with steroids.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...