Related Experiment Videos
Measurement accuracy of aluminium content in bone
H O Hellström1, U Lindh, B Mjöberg
1Department of Orthopedics, Uppsala University Hospital Sweden.
Upsala Journal of Medical Sciences
|July 13, 2000
Abstract:
The aluminium content in bone has been related in several ways: to the weight of wet bone, to the weight of dry bone, to the weight of bone-ash and to the calcium content of bone. We determined the accuracy and precision of measurement (using an inductively coupled mass-spectrometer) in 30 bone samples taken from one patient. The coefficient of variation of the aluminium/weight-quotient was 12.4 per cent for wet bone, 4.7 for dry bone and 5.0 for bone ash; and the coefficient of variation of the aluminium/calcium-weight-quotient was 7.5 per cent. Thus, the aluminium content in bone seems to be best related to the weight of dry bone.