Related Experiment Video
Updated: Aug 13, 2026

Multi-analyte Biochip (MAB) Based on All-solid-state Ion-selective Electrodes (ASSISE) for Physiological Research
Published on: April 18, 2013
Acid-base control for biocatalysis in organic media: new solid-state proton/cation buffers and an indicator
1Department of Pure and Applied Chemistry, University of Strathclyde, Glasgow, UK.
Abstract:
Although great care is generally taken to buffer aqueous enzyme reactions, active control of acid-base conditions for biocatalysis in low-water media is rarely considered. Here we describe a new class of solid-state acid-base buffers suitable for use in organic media. The buffers, composed of a zwitterion and its sodium salt, are able to set and maintain the ionisation state of an enzyme by the exchange of H+ and Na+ ions. Surprisingly, equilibrium is established between the different solid components quickly enough to provide a practical means of controlling acid-base conditions during biocatalysed reactions. We developed an organosoluble chromoionophore indicator to screen the behaviour of possible buffer pairs and quantify their relative H+/Na- exchange potential. The transesterification activity of an immobilised protease, subtilisin Carlsberg, was measured in toluene in the presence of a range of buffers. The large observed difference in rates showed good correlation with that expected from the measured exchange potentials. The maximum water activities accessible without formation of hydrates or solutions of the buffers are reported here. The indicator was also used to monitor, for the first time in situ, changes in the acid-base conditions of an enzyme-catalysed transesterification reaction in toluene. We found that even very minor amounts of an acidic by-product of hydrolysis were leading to protonation of the enzyme, resulting in rapid loss of activity. Addition of solid-state buffer was able to prevent this process, shortening reaction times and improving yields. Solid-state buffers offer a general and inexpensive way of precisely controlling acid-base conditions in organic solvents and thus also have potential applications outside of biocatalysis.
Related Concept Videos
Buffers
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Titration in Nonaqueous Solvents
Titration of Polyprotic Base with a Strong Acid
Titration of a Weak Acid with a Strong Base
Buffers: Overview

