Related Experiment Videos
Wear and surface roughness of current prosthetic composites after toothbrush/dentifrice abrasion
N Tanoue1, H Matsumura, M Atsuta
1Department of Fixed Prosthodontics, Nagasaki University School of Dentistry, Nagasaki, Japan. t-naomi@net.nagasaki-u.ac.jp
Statement Of Problem:
Surface changes of prosthetic composites caused by toothbrushing are known, although composite materials have been improved and are now widely used for various kinds of prosthetic restorations.
Purpose:
This study evaluated the influence of toothbrushing on abrasive wear and surface roughness of current prosthetic composites.
Material And Methods:
Seven composite materials (Artglass, Axis, Cesead II, Conquest Sculpture, Estenia, Infis, and Targis) were assessed, and a machinable ceramic material (Cerec 2 Vitablocs) was used as a reference. Composite specimens polymerized with their proprietary curing units and sectioned ceramic specimens were stored in water for 14 days, and subsequently subjected to toothbrush-dentifrice abrasion. The amount of vertical loss and the surface roughness of each specimen after 20,000 strokes were determined with a profilometer. Average values of groups of 5 specimens were compared with ANOVA and Duncan new multiple range test.
Result:
Significantly (P < .05) less wear was observed with respect to the Targis (10.01 microm; SD = 0.53 microm) and Estenia (13.04 microm; 1.95 microm) materials than for the other composites assessed, whereas Artglass (34.08 microm; 3.66 microm) and Conquest Sculpture (31.78 microm; 4.67 microm) materials demonstrated the most wear. The least surface roughness was exhibited by Conquest Sculpture (Ra, 0.54 microm; 0.07 microm) material, and the greatest by Cesead II (1.10 microm; 0.13 microm). Ceramic material showed a more wear-resistant (4.54 microm; 0.79 microm) and smoother (0.26 microm; 0.02 microm) surface than any of the composite materials.
Conclusion:
Abrasion and surface roughness of the prosthetic composites caused by toothbrushing varied in accordance with the material. Type of prosthetic composite significantly influenced the surface condition after toothbrushing.