Aortic valve replacement with concomitant annular enlargement for small aortic annulus of less than 19 mm
H Takakura1, T Sasaki, K Hashimoto
1Department of Cardiovascular Surgery, Saitama Cardiovascular and Respiratory Center, 1696 Itai Kounan-machi, Osato-gun, Saitama 360-0105, Japan.
Abstract:
Three female patients with aortic stenosis associated with a severely small annulus underwent aortic valve replacement. In intraoperative measurements, a 19-mm obtulator could not pass through the aortic annulus in each case. We therefore concluded that it would be difficult to implant an appropriate-sized prosthesis in a routine fashion, so we performed an annular enlargement in a modified Nicks procedure. By using a wide teardrop-shaped patch for enlargement and slightly tilting insertion of a prosthesis, a 21 mm bileaflet mechanical prosthesis could be inserted into the enlarged annulus. Despite being a simpler method than other enlarging procedures, a two- or three-sizes larger prosthesis than the native annulus can be inserted with relative ease. Thus, the use of a 19 mm mechanical prosthesis may be avoidable in most adult cases.