Related Experiment Video
Updated: Oct 15, 2026

Scanning Skeletal Remains for Bone Mineral Density in Forensic Contexts
Published on: January 29, 2018
Racial and geographic differences of Wiberg's angle from 400 ultrasonographic normal hips in Italian and Brazilian
C Milani1, A Ishida, J Laredo Filho
1Department of Orthopedic Surgery, Federal University of São Paulo-Escola Paulista de Medicina, Brazil.
Insights
Brazilian infants showed better acetabular roof complex conformation than Italian infants, based on Wiberg center edge angle (CEA) measurements from hip sonographies. This study compared 100 Brazilian and 100 Italian infants aged 15-90 days.
Area of Science:
- Pediatric Orthopedics
- Medical Imaging
- Comparative Anatomy
Background:
- Hip sonography is crucial for assessing infant hip joint development.
- Graf's classification is a standard for evaluating hip joint normality ultrasonographically.
- The Wiberg center edge angle (CEA) is a key metric for acetabular development.
Purpose of the Study:
- To compare the acetabular roof complex conformation between Brazilian and Italian infants using CEA.
- To validate a novel methodology for CEA measurement in infant hip sonographies.
- To establish normative data for CEA in healthy infants from different ethnic backgrounds.
Main Methods:
- Sonographic hip evaluations were performed on 200 infants (100 Brazilian, 100 Italian), aged 15-90 days.
- Infants with normal hip joints (Graf type 1a and 1b) were included.
- A custom-developed graphic computer program was used for precise Wiberg center edge angle (CEA) measurements.
Main Results:
- Statistical analysis revealed a significantly better conformation of the acetabular roof complex in Brazilian infants compared to Italian infants.
- The developed methodology for CEA measurement proved effective and consistent.
- No significant differences were noted in infant age or hip joint normality classification between the groups.
Conclusions:
- Infant hip development, specifically acetabular roof conformation, may exhibit ethnic variations.
- The Wiberg center edge angle (CEA) is a reliable indicator for detecting subtle differences in acetabular development.
- Further research is warranted to explore the implications of these findings for early diagnosis and treatment of hip dysplasia.
Abstract:
The Wiberg center edge angle (CEA) of 400 hip sonographies among 200 infants, 100 Italians and 100 Brazilians, aged from 15 days to 90 days, whose hip joints were considered normal, from the ultrasonographic point of view (1a and 1b) according to Graf's classification were measured. For the CEA measurements in the studied material, the authors used their own methodology developed for this purpose, which is based on basic geometric concepts and applied by one graphic computer program. In the studied material, the statistical analysis of the results obtained in the measurement of the CEA showed a better conformation of the acetabular roof complex in the Brazilian infants compared with the Italian.

