Related Experiment Video
Updated: Jun 29, 2026

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
Published on: May 2, 2018
Receiver operating characteristic analysis for intelligent medical systems--a new approach for finding confidence
J B Tilbury1, P W Van Eetvelt, J M Garibaldi
1SMART Medical Systems Research Group, School of Electronic Communication and Electrical Engineering, University of Plymouth, U.K.
Abstract:
Intelligent systems are increasingly being deployed in medicine and healthcare, but there is a need for a robust and objective methodology for evaluating such systems. Potentially, receiver operating characteristic (ROC) analysis could form a basis for the objective evaluation of intelligent medical systems. However, it has several weaknesses when applied to the types of data used to evaluate intelligent medical systems. First, small data sets are often used, which are unsatisfactory with existing methods. Second, many existing ROC methods use parametric assumptions which may not always be valid for the test cases selected. Third, system evaluations are often more concerned with particular, clinically meaningful, points on the curve, rather than on global indexes such as the more commonly used area under the curve. A novel, robust and accurate method is proposed, derived from first principles, which calculates the probability density function (pdf) for each point on a ROC curve for any given sample size. Confidence intervals are produced as contours on the pdf. The theoretical work has been validated by Monte Carlo simulations. It has also been applied to two real-world examples of ROC analysis, taken from the literature (classification of mammograms and differential diagnosis of pancreatic diseases), to investigate the confidence surfaces produced for real cases, and to illustrate how analysis of system performance can be enhanced. We illustrate the impact of sample size on system performance from analysis of ROC pdf's and 95% confidence boundaries. This work establishes an important new method for generating pdf's, and provides an accurate and robust method of producing confidence intervals for ROC curves for the small sample sizes typical of intelligent medical systems. It is conjectured that, potentially, the method could be extended to determine risks associated with the deployment of intelligent medical systems in clinical practice.
More Related Videos
07:10Application of Biochip Microfluidic Technology to Detect Serum Allergen-specific Immunoglobulin E (sIgE)
Published on: April 21, 2019
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Related Concept Videos
Confidence Intervals
A confidence...
Interpretation of Confidence Intervals
Confidence intervals have confidence coefficients that are crucial for their interpretation. The most common confidence coefficients are 0.90, 0.95, and 0.99, which can be written as percentages–90%, 95%, and 99%, respectively.
Suppose a person calculates a confidence interval with a confidence coefficient of 0.95. In that case, they can...
Uncertainty: Confidence Intervals
Receiver Operating Characteristic Plot