Related Experiment Video
Updated: Aug 7, 2026

Stabilizing Hepatocellular Phenotype Using Optimized Synthetic Surfaces
Published on: September 26, 2014
Development of a hybrid artificial liver using a polyurethane foam/hepatocyte-spheroid packed-bed module
H Ijima1, K Nakazawa, S Koyama
1Department of Chemical Systems and Engineering, Graduate School of Engineering, Kyushu University Fukuoka, Japan.
Abstract:
Primary dog hepatocytes spontaneously formed spheroids in the pores of polyurethane foam (PUF) within 1-2 days of stationary culture. The spheroids, about 100-150 microm in diameter, partly attached to the surface and immobilized inside these pores. The lidocaine disappearance rate decreased to about 4 microg/10(5) viable cells/day for 10 days, while in the PUF/spheroid culture the rate was maintained at almost the initial level of 8 microg/10(5) viable cells/day for 10 days. Then, two scales of PUF packed-bed modules were designed. A small module (PUF volume; 14.5 cm3) was used for in vitro culture to investigate optimum culture conditions, and a large module (PUF volume; 300 cm3) was designed for dog experiments. Hepatocytes inoculated in these modules also formed spheroids and maintained almost the same activity of albumin secretion rate (111 microg/cm3 PUF/day in the small module and 87.7 microg/cm3 PUF/day in the large module). These results indicate that the PUF packed-bed module containing hepatocyte-spheroids is promising as a hybrid artificial liver.