Transit time flow measurement: experimental validation and comparison of three different systems
G Beldi1, A Bosshard, O M Hess
1Department of Cardiovascular Surgery, University Hospital Insel, Bern, Switzerland.
The Annals of Thoracic Surgery
|August 2, 2000
Summary
Transit time flow measurements are validated for vascular surgery quality control. Second-order correction ensures accurate and precise blood flow assessment across different conditions.
Area of Science:
- Vascular Surgery
- Medical Devices
- Hemodynamics
Background:
- Accurate blood flow measurement is crucial for vascular surgery quality control.
- Detecting low-flow states is essential to prevent adverse patient outcomes.
- Validation of blood flow measurement systems is needed for clinical application.
Purpose of the Study:
- To validate three different flow systems for measuring absolute blood flow.
- To assess the accuracy and reproducibility of transit time flow measurements.
- To compare system performance under various experimental conditions.
Main Methods:
- Experimental flow model using arteries and veins.
- Measurements conducted with blood and saline at different temperatures.
- True flow determined by volume sampling as the reference method.
Main Results:
- Initial correlation coefficients (0.71-0.92) showed variability.
- Systematic over/underestimation of transit time flow was observed.
- Second-order correction resulted in excellent correlations (0.93-0.95) regardless of medium or temperature.
Conclusions:
- Transit time flow measurements are exact and reproducible.
- Second-order correction significantly improves accuracy and precision.
- The three evaluated systems demonstrated minimal performance differences.
More Related Videos
Related Concept Videos
Fast Reactions
Fast reactions occurring in times shorter than the time needed to mix reactants pose a unique challenge for investigation. In a liquid-phase continuous-flow system, reactants A and B are swiftly pushed into the mixing chamber, where mixing occurs within 1 ms. The reaction mixture then flows through an observation tube, and one measures light absorption to determine species concentrations at various points of the tube. This method is most appropriate when relatively large volumes of reactants...
Noncompartmental Analysis: Mean Transit, Absorption and Dissolution Time
When drugs are administered extravascularly, a comprehensive evaluation through noncompartmental analysis becomes imperative. This analytical approach considers various parameters that play a crucial role in understanding the pharmacokinetics of these drugs.
One of the key parameters is the mean transit time (MTT), which refers to the total duration required for drug molecules to transit through the body. MTT is determined by calculating the ratio of the area under the moment curve to the area...
One of the key parameters is the mean transit time (MTT), which refers to the total duration required for drug molecules to transit through the body. MTT is determined by calculating the ratio of the area under the moment curve to the area...
Pipe Flowrate Measurement
In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
The orifice meter is a simple,...
Pipe Flowrate Measurement: Problem Solving
A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is achieved...