The +10 diopter lens occluder.

N Benegas1, B J Kushner, G V Morton

  • 1Department of Ophthalmology and Visual Sciences, University of Wisconsin, Madison, WI 53705, USA.

Archives of Ophthalmology (Chicago, Ill. : 1960)
|August 2, 2000
PubMed
Summary

A +10 diopter lens allows clear visualization of the eye during cover tests, providing strabismus measurements similar to opaque occluders. This method is effective for assessing eye alignment.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

An unusually large incyclotropia associated with dysthyroid ophthalmopathy.

The British journal of ophthalmology·2008
Same author

Comparison of a new, minimally invasive strabismus surgery technique with the usual limbal approach for rectus muscle recession and plication.

The British journal of ophthalmology·2006
Same author

Recently acquired diplopia in adults with long-standing strabismus.

Archives of ophthalmology (Chicago, Ill. : 1960)·2001
Same author

Further debate regarding surgery for esotropia, +/- accommodative; cyclovertical muscles, Gobin's theories re "sagitallization"; letters No. 3,4 & 5.

Binocular vision & strabismus quarterly·2001
Same author

Grand rounds #64: a case of deterioration of ocular motility in a patient with unilateral type I Duane syndrome after contralateral orbital decompression.

Binocular vision & strabismus quarterly·2001
Same author

Anterior segment ischemia after surgery on 2 vertical rectus muscles augmented with lateral fixation sutures.

Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus·2001

Area of Science:

  • Ophthalmology
  • Vision Science

Background:

  • The cover test is crucial for diagnosing strabismus.
  • Visualizing the eye during the cover test is often challenging.
  • A +10 diopter lens may serve as an effective occluder for improved visualization.

Purpose of the Study:

  • To evaluate the efficacy of a +10 diopter lens as an occluder during the cover test.
  • To compare measurements of strabismus obtained using a +10 diopter lens versus a standard opaque occluder.

Main Methods:

  • Strabismus angles were measured in 65 patients with various forms of strabismus.
  • Measurements were taken using both a +10 diopter lens and an opaque occluder.
  • Findings from both occluder types were compared for agreement.

Main Results:

  • Excellent visualization of the dissociated eye was achieved through the +10 diopter lens in all patients.
  • Measurements using the +10 diopter lens agreed within 3 prism diopters of the opaque occluder in 64 out of 65 patients.
  • One patient showed a 5 prism diopter difference between the two occluders.

Conclusions:

  • A +10 diopter lens is a viable alternative to standard occluders for the cover test.
  • It offers clear visualization of the dissociated eye.
  • Measurements obtained are comparable to those using opaque occluders, aiding in strabismus assessment.