Related Experiment Video
Updated: Aug 12, 2026

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Uncemented total knee replacement - the favourable influence of low over high pressure drainage
1Australian Institute of Musculo-Skeletal Research, 286 Pacific Highway, 2065, Crows Nest, NSW, Australia
Abstract:
The post-operative blood loss following an uncemented total knee replacement is substantial and can be affected by the vacuum pressure in the suction drains. One hundred and nine patients undergoing 122 uncemented total knee replacements were monitored to ascertain the influence of high or low vacuum drains on blood loss. Low volume drains produced a statistically significant reduction in blood loss compared to high vacuum drains [mean 1364 ml vs. mean 1695 ml (P<0.0062)]. Our findings revealed that high suction pressure drains are not necessary, and may be detrimental when used following uncemented total knee replacement.