Related Experiment Video
Updated: Aug 7, 2026

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Gastric distension and ventilation during laparoscopic cholecystectomy: LMA-Classic vs. tracheal intubation
J R Maltby1, M T Beriault, N C Watson
1Department of Anesthesia, University of Calgary, Alberta, Canada. maltby@ucalgary.ca
Purpose:
The standard laryngeal mask airway LMA-Classic was designed as an alternative to the endotracheal tube (ETT) or the face mask for use with either spontaneous or positive pressure ventilation. Positive pressure ventilation may exploit leaks around the LMA cuff, leading to gastric distension and/or inadequate ventilation. We compared gastric distension and ventilation parameters with LMA vs ETT during laparoscopic cholecystectomy.
Methods:
One hundred and one, ASA I-II adults scheduled for elective laparoscopic cholecystectomy were randomly assigned to LMA-Classic or ETT. Patients with BMI >30 kg x m(-2), hiatus hernia or gastroesophageal reflux were excluded. Following induction of anesthesia, an in-and-out orogastric tube was passed to decompress the stomach before insertion of the LMA (women size #4, men size #5) or ETT (women 7 mm, men 8 mm). Anesthesia was maintained with isoflurane in nitrous oxide and oxygen (FIO2 0.3-0.5), rocuronium and fentanyl. The surgeon, blinded to the type of airway, scored gastric distention 0-10 at insertion of the laparoscope and immediately before removal at the end of the surgical procedure.
Results:
Incidence and degree of change in gastric distension were similar in both groups. Ventilation parameters during insufflation (mean +/- SD) for LMA and ETT were: S(P)O2 98 +/- I vs 98 +/- I, P(ET)CO2 38 +/- 4 vs 36 +/- 4 mm Hg and airway pressure 21 +/- 4 vs 23 +/- 3 cm water.
Conclusion:
Positive pressure ventilation with a correctly placed LMA-Classic of appropriate size permits adequate pulmonary ventilation. Gastric distension occurs with equal frequency with either airway device.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques