Purpose:
To present a patient who developed cardiac tamponade during insertion of an inferior vena cava (IVC) filter. Intraoperative transesophageal echocardiography (TEE) was used as a means to diagnose the cardiac tamponade and to facilitate guiding of pericardiocentesis.
Clinical Features:
A 45-yr-old man with protein S deficiency complicated by repeated attacks of deep vein thrombosis and pulmonary thromboembolism was scheduled for insertion of an IVC filter. He had history of chronic renal insufficiency, heart failure, and cerebral infarction with mild left hemiparesis. Current medication included diltiazem (30 mg, I tab tid ), prednisolone (5 mg, 2 tabs qd ), and warfarin (2.5 mg daily). Preoperative transthoracic echocardiography demonstrated bilateral pleural effusions, moderate mitral regurgitation and tricuspid regurgitation, left atrial appendage thrombus and severe generalized hypokinesia of left ventricle. Nuclear medicine examination by (99)Tc showed ejection fractions of left ventricle and right ventricle as 20% and 22%, respectively. Under the impression of protein S deficiency with multiple attacks of thromboembolism and failure of anticoagulant therapy, he was arranged for the procedure of vena caval filter insertion. Unfortunately, iatrogenic cardiac tamponade occurred during the course of the procedure with rapid hemodynamic deterioration. Because of the expedient of routine monitoring of cardiac condition with TEE, a prompt diagnosis was made. We successfully improved the patient's hemodynamic status after transthoracic echo-guided pericardiocentesis.
Conclusion:
Intraoperative TEE is recommended to be used routinely in patients undergoing vena cava filter procedures. The availability of echocardiographic monitoring in the operation room allows the confirmation of the diagnosis and facilitation pericardiocentesis.
Related Concept Videos
Venous Thrombosis III: Interprofessional Care
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization I: Pre-Procedure Overview