Estimates of repolarization dispersion from electrocardiographic measurements
M S Fuller1, G Sándor, B Punske
1Nora Eccles Harrison Cardiovascular Research and Training Institute, University of Utah School of Medicine, Salt Lake City, Utah 84112-5000, USA. fuller@cvrti.utah.edu
Background:
Repolarization dispersion (Rd) is frequently mentioned as a predictor of cardiac abnormalities. We present a new measure of Rd based on the root-mean-square (RMS) curve of an ECG lead set and compare its performance with that of the commonly used QT dispersion (QTd) measure with the use of recovery times measured from directly recorded canine electrograms.
Methods And Results:
Using isolated, perfused canine hearts suspended in a torso-shaped electrolytic tank, we simultaneously recorded electrograms from 64 epicardial sites and ECGs from 192 "body surface" sites. RMS curves were derived from 4 lead sets: epicardial, body surface, precordial, and a 6-lead optimal set. Repolarization was altered by changing cycle length, temperature, and activation sequence. Rd, calculated directly from recovery times of the 64 epicardial potentials, was then compared with the width of the T wave of the RMS curve and with QTd for each of these 4 lead sets. The correlation between T-wave width and Rd for each lead set, respectively, was epicardium, 0.91; body surface, 0.84; precordial, 0.72; and optimal leads, 0.81. The correlation between QTd and Rd for each lead set was epicardium, 0.46; body surface, 0.47; precordial, 0.17; and optimal leads, 0.11.
Conclusions:
RMS curve analysis provides an accurate method of estimating Rd from the body surface. In contrast, QTd analysis provides a poor estimate of Rd.
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Dysrhythmias V: Evaluating Dysrhythmias