Performance-enhanced "tunable" capillary microwave-induced plasma mass spectrometer for gas chromatography detection
1Department of Chemistry, Center for Field Analytical Studies and Technology, Tufts University, Medford, Massachusetts 02155, USA.
Abstract:
Improvements in the stability and performance of a capillary microwave-induced plasma-mass spectrometer (MIP-MS) were achieved by optimizing power transfer to the cavity using a tunable coaxial MIP. The MIP, operating at atmospheric pressure, was sustained with 30 mL/min He and 60 W of power. Measurement precision and sensitivity for the standard waveguide and coaxial systems were determined using 16 organochlorine pesticide solutions separated by gas chromatography (GC). The linear dynamic range obtained with the tunable MIP-MS extended over 3 orders of magnitude, a 10 time improvement with respect to the standard MIP. Detection limits were between 3 and 19 pg of Cl mol(-1) s(-1), 7 times lower than the detection limits obtained with the nontunable MIP-MS. Analysis of pesticides containing sulfur atoms was also possible, further demonstrating multielement MIP-MS detection. Excellent accuracy (10% recovery) and precision (5% RSD) were found for the detection of the pesticides in a petroleum-contaminated reference soil. By placing the GC column at the plasma expansion stage, molecular fragmentation of a mixture of volatile organic compounds was also demonstrated. With the MS operated in the selected ion monitoring mode, measurement sensitivity was approximately 500 pg/s per compound.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
04:19An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II