Related Experiment Video
Updated: Aug 7, 2026

Heterotopic Auxiliary Rat Liver Transplantation With Flow-regulated Portal Vein Arterialization in Acute Hepatic Failure
Published on: September 13, 2014
Conditions required for a hybrid artificial liver support system using a PUF/hepatocyte-spheroid packed-bed module
H Ijima1, K Nakazawa, S Koyama
1Department of Chemical Systems and Engineering, Graduate School of Engineering, Kyushu University, Fukuoka, Japan.
Abstract:
We studied the effects of a hybrid artificial liver support system we developed on dogs with hepatic failure. The system consisted of a multi-channel polyurethane foam packed-bed culture module, including primary dog hepatocyte spheroids. Blood ammonia was well metabolized by 20 g hepatocytes, but the other functions such as glucose concentration, total bile acid concentration, and survival time required 30 g hepatocytes to improve conditions. We found that we should use a culture substratum that easily forms spheroids, and that an artificial liver module should be used as soon as possible after spheroid formation by hepatocytes in the module.