Solid-phase extraction of phenols

I Rodríguez1, M P Llompart, R Cela

  • 1Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Química, Universidad de Santiago de Compostela, Spain.

Related Concept Videos

Hydrolysis of Chlorobenzene to Phenol: Dow Process01:10

Hydrolysis of Chlorobenzene to Phenol: Dow Process

Simple aryl halides do not react with nucleophiles under normal conditions. However, the reaction can proceed under drastic conditions involving high temperatures and high pressure to give the substituted products. For example, chlorobenzene is converted to phenol using aqueous sodium hydroxide at 350 °C under high pressure by the Dow process. The reaction follows an elimination-addition mechanism involving a benzyne intermediate. Here, the chloride ion is eliminated to generate the benzyne...
Precipitation and Co-precipitation01:17

Precipitation and Co-precipitation

Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
Extraction: Effects of pH00:53

Extraction: Effects of pH

Consider a neutral form of an amine, B, with a partition coefficient, K, in a liquid mixture containing organic and aqueous phases. The pH of the aqueous phase affects the charge on acidic and basic solutes, and the charged form is usually more soluble in the aqueous phase. Suppose the conjugate acid form of the amine is soluble only in the aqueous phase while the base form is soluble in both phases. Then the distribution coefficient, D, can be given as the ratio of amine concentration in the...
Extraction: Advanced Methods00:56

Extraction: Advanced Methods

Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is formed in...
Gas Chromatography: Types of Columns and Stationary Phases01:17

Gas Chromatography: Types of Columns and Stationary Phases

Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process: