How precise are measurements of unit-cell dimensions from single crystals?
1Department of Chemistry, Technion-Israel Institute of Technology, Haifa 32000, Israel. chr03fh@tx.technion.ac.il
Abstract:
The results of single-site and many-site measurements of cell dimensions from single crystals are compared for Bond and four-circle diffractometers using samples of corundum (essentially pure rhombohedral alpha-Al2O3, aluminum oxide) of high diffraction quality, where the effects of small changes in temperature and composition (Cr2O3, chromium oxide, in solid solution) can be taken into account. Similar comparisons are made for four-circle diffractometer measurements on ruby (alpha-Al2O3, with 0.46 wt % Cr in solid solution). The precisions are some parts in 10(5). There is partial support for the Taylor-Kennard [Acta Cryst. (1986), B42, 112-120] dictum that standard uncertainties (s.u.s) of cell parameters from routine four-circle diffractometer measurements are less than those for many-site measurements by factors of 5 for cell lengths and 2.5 for cell angles. For organic crystals, independent repetitions of adequate quality for comparison and analysis of routine four-circle diffractometer measurements are available only for alpha-oxalic acid dihydrate and anthracene. The experimental standard uncertainties given for these two crystals agree reasonably well with the sample s.u.s at room temperature, but appreciably less well at approximately 100 K, again giving partial support to the Taylor-Kennard dictum. The relation between specimen characteristics and attainable precision is emphasized; the precisions for routine measurements on good quality organic crystals are some parts in 10(4). Area-detector measurements of cell dimensions have also been appraised; currently published s.u.s from such measurements appear to be highly unreliable, and this is supported by a recent analysis of the operation of such diffractometers [Paciorek et al. (1999). Acta Cryst. A55, 543-557]. Formulation of a standard protocol for such measurements is badly needed. The dangers inherent in high degrees of replication are illustrated by recounting Kapteyn's Parable of the Chinese Emperor. Attention is drawn to the fact that there has been little improvement in claimed precisions over the past 40-60 years.
More Related Videos
10:32Sample Preparation and Transfer Protocol for In-Vacuum Long-Wavelength Crystallography on Beamline I23 at Diamond Light Source
Published on: April 23, 2021
07:08Crystallization and In Situ Room Temperature Data Collection Using the Crystallization Facility at Harwell and Beamline VMXi, Diamond Light Source
Published on: March 8, 2024
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Crystal Density
Law of Rational Indices
Determination of Crystal Structures
Imperfections in Crystal Structure: Point, Line and Plane Defects