Related Experiment Video
Updated: Aug 17, 2026

Rapid Point-of-Care Assay of Enoxaparin Anticoagulant Efficacy in Whole Blood
Published on: October 12, 2012
Antithrombin III in patients with severe sepsis: a pharmacokinetic study
W Ilias1, W List, J Decruyenaere
1Krankenhaus der Barmherzigen Brüder, Anaesthesiology and Intensive Care Medicine, Vienna, Austria.
Objectives:
To evaluate the safety, pharmacokinetics, and the practicability of two different antithrombin III (AT III) high-dose regimens in patients with severe sepsis.
Design:
Prospective, open, randomized, 2 parallel groups, multinational clinical trial.
Setting:
Eleven academic medical center intensive care units (ICU) in Austria, Belgium, Denmark, Germany, Norway and Sweden.
Patients:
Thirty-three patients with severe sepsis who received standard supportive care and antimicrobial therapy, in addition to the administration of AT III.
Interventions:
Patients received an intravenous loading dose of 6,000 IU AT III followed by either intermittent bolus infusions of 1,000 IU AT III every 4 h or a continuous infusion of 250 IU AT III/h for 4 days, resulting in a total dose for both dosage regimens of 30,000 IU AT III.
Measurements:
All patients were evaluated for safety and all but one for pharmacokinetics.
Results And Conclusions:
The administration of AT III was safe and well tolerated. The overall 28-day all-cause mortality was 30% (43% intermittent bolus infusions; 21% continuous infusion). The mean probability of dying according to the SAPS II was 48%. The difference in mortality between both groups was within the range of chance. AT III plasma levels were elevated from low baseline levels to above 120% soon after onset of AT III therapy and remained at these levels for the treatment phase of 4 days. Functional and immunologic levels of AT III corresponded very well. With an overall median volume of distribution of 4.5 l (range: 2.4-6.5 l), AT III only moderately extended beyond plasma. The overall median elimination half-life was 18.6 h (range: 5.1-37.4). Overall, median response was 1.75% per IU/kg (range: 1.14-2.8). The variability of elimination parameters was quite noteworthy (CV = 41-59%), whereas distribution-related parameters showed a moderate variability (CV = 24%). In spite of this variability, both high-dose IV regimens reliably provided AT III levels above 120% for all but one patient. An increased mortality was observed for patients with a distribution volume exceeding 4.5 l (or a response < 1.7% per IU/kg). AT III distribution volumes above 4.5 l might indicate a capillary leak phenomenon. The continuous infusion regimen was slightly preferred by the investigators with regard to practicability.
More Related Videos
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Venous Thrombosis III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care