Atrial sensing performance of a single-lead VDD pacing system during physical activities
Related Experiment Video
Updated: Oct 13, 2026

Translational Rabbit Model of Chronic Cardiac Pacing
Published on: January 6, 2023
F Ertaş1, R Karaoğuz, M Güldal
1Department of Cardiology, Medical School of Ankara, University, Turkey.
Abstract:
This study was undertaken to evaluate the atrial sensing performance of a single-lead atrial synchronous-ventricular pacing system during various physical activities on late follow-up. Fourteen patients (mean age 55 +/- 17 years) with a third-degree or high-degree atrioventricular block and normal sinus node function were treated with the single-lead Thera VDD (Medtronic, Inc, Minneapolis, MN) pacemaker system. Mean P-wave amplitude at implantation was 3.2 +/- 1.3 mV. To assess the VDD system performance, P-wave amplitudes during various physical maneuvers (supine, sitting, deep breathing, standing, and exercise; respectively) were measured and atrial sensing was evaluated at a mean follow-up of 11 +/- 4 months. During deep breathing, minimum and maximum P-wave amplitudes (0.8 +/- 0.7, 1.2 +/- 1.0 mV, respectively) were found to be significantly lower than the standing position (minimum, 1.1 +/- 0.9, maximum, 1.4 +/- 1.1 mV P = .02 in both). No significant difference was found during other physical maneuvers. During the testing maneuvers, atrial undersensing was observed in 8 patients (57%) at the nominal atrial sensitivity of 0.5 mV. After increasing the atrial sensitivity (0.25 mV), no sensing failure was observed in these patients. It has been concluded that Medtronic Thera VDD system is a safe and reliable device with an easy implantation technique providing effective atrioventricular synchronization. The sensing problems, which may occur on late follow-up, can be corrected successfully by reprogramming. To achieve an optimal atrial sensing function in patients with a single-lead VDD pacing, we recommend that the atrial sensing capability should be examined in various physical maneuvers.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
07:49A Pacing-Controlled Procedure for the Assessment of Heart Rate-Dependent Diastolic Functions in Murine Heart Failure Models
Published on: July 21, 2023
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Holter Monitor: 24-Hour Monitoring
Dysrhythmias V: Evaluating Dysrhythmias
Special considerations while measuring pulse
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: