An evaluation of prosthetic aortic valves using transesophageal echocardiography: the double-envelope technique
A D Maslow1, J M Haering, S Heindel
1Departments of Anesthesia and Cardiology, Beth Israel-Deaconess Medical Center. Mass General Hospital, Boston, MA, USA. amaslow@lifespan.org
Unlabelled:
The conventional continuity equation uses nonsimultaneous measurements of blood flow velocities through the left ventricular outflow tract and across the aortic valve to calculate aortic valve area (AVA). We have noted that both velocities can be simultaneously obtained from continuous wave (CW) Doppler analysis (double-envelope [DE]). We hypothesize that prosthetic AVA can be calculated by using the DE technique, during transesophageal echocardiography (TEE). Prosthetic AVA was calculated in 41 of 45 patients immediately after aortic valve replacement by using the DE/AVA technique. Left ventricular outflow tract diameter was obtained from an esophageal view, while subvalvular (V(1)) and valvular (V(2)) peak velocities were simultaneously obtained from transgastric views by using CW Doppler. Prosthetic AVA and V(1)/V(2) ratio (Doppler velocity index) were calculated. V(1) was also measured by using pulse wave Doppler, as is conventionally done. Twenty-three Carbomedic (CM) and 18 Carpentier-Edwards (CE) AVA were evaluated. DE/AVAs for CM and CE valves correlated and agreed with that reported by the manufacturer (CM r(2) = 0.91, mean bias -0.25 cm(2) [SD 0.18]; CE r(2) = 0.73, mean bias -0.02 cm(2) [SD 0.27]). Calculated Doppler velocity index values agree with available data (mean bias 0.03 [SD 0.05]). The V(1) obtained by using the DE method was nearly identical to the V(1) obtained by using pulse wave (r(2) = 0.95, mean bias 0.02 m/s [SD 0.04 m/s]). TEE assessment of prosthetic AVA using the DE technique agrees with data reported by the manufacturer. Obtaining subvalvular and valvular velocities from the same CW Doppler trace may simplify the continuity equation and help avoid errors caused by beat-to-beat changes in blood flow. Quantitative prosthetic aortic valve assessment can be performed, on-line, with TEE by using the DE technique.
Implications:
Quantitative assessment of prosthetic aortic valve area can be performed on-line by using transesophageal echocardiography using the double envelope technique.
Related Concept Videos
Routes of Drug Administration: Parenteral
The intravenous route (IV) of drug administration can be further categorized into two types. The bolus injection administers the entire dose rapidly, while an intravenous infusion slowly delivers smaller doses steadily.
The IV route is often...
Inhaled Medications
Insulin: Biosynthesis, Chemistry, and Preparation
Damage or functional impairment of β-cells inhibits insulin production, leading to diabetes. Diabetes treatment...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Oral Hypoglycemic Agents: Glinides