High Precision Zinc Isotopic Measurements Applied to Mouse Organs
Published on: May 22, 2015
Error-systematics of determining simultaneously the (6 )Li /(7)Li and the (10)B/(11)B abundance ratios as
1Fuel Chemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India.
Abstract:
In the Li(2)BO(2)(+) ion beam method of isotopic analysis of elements, the (two) analyte isotopic abundance ratios (E( i)'s) are determined by solving a set of (two) simultaneous equations: f( i)(E( i)'s) = R( i) +/- delta( i), (i = 1, 2) where the R( i)'s are the measured isotopic molecular abundance ratios. We have shown recently that, in the process of solution of these equations, the experimental errors (delta( i)'s) are transformed into the actual errors of analysis, delta(E)'s, through some multiplication factors (MFs). For a given isotopic abundance distribution (IAD) of the Li(2)BO(2)(+) ions, the MFs are shown to depend on the combination of two molecular pairs (CTMPS) used as the monitor pairs for measurements, thereby indicating the requirement of careful selection of monitor pairs for avoiding large (propagated) errors in analysis. In this work, we study how the requirements for a correct analysis vary with the IADs of the elements to be analyzed. The results not only lay great emphasis on the need for proper selection, but also show that no CTMPS can be identified as the universal monitor pairs irrespective of molecular IAD. These observations are, moreover, independent of the actual isotopic abundances of the monitor ions and/or the achievable measurement accuracy (delta( i)). It is noted further that, depending on the IADs of the analyte elements and hence the specific IAD of the Li(2)BO(2)(+) ions, it may also happen that none of the different possible CTMPS really fits the criteria as the recommended monitor pairs, and then one has to ensure that the measurements are not only accurate but as perfect as possible (delta( i)'s --> 0) so as to achieve a reasonable accuracy in analysis. These findings are explained in terms of variations of MFs as a function of molecular IAD, and elaborated using experimental data. A comparative discussion on the determination of both (6)Li/(7)Li and (10)B/(11)B abundance ratios together, and that of either of them, as Li(2)BO(2)(+), is also presented with a view to highlighting different possible aspects of the involvement of computation steps in analysis. The important implication of the present investigation is that it sets guidelines for the general problem of accurately analyzing unknown samples, irrespective of their sources of origin. Copyright 2000 John Wiley & Sons, Ltd.
More Related Videos
12:47Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
06:53Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
Related Concept Videos
Isotopes
Atomic Mass
Mass Spectrometry: Isotope Effect
Propagation of Uncertainty from Systematic Error
Mass Spectrum: Interpretation
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences