Medial displacement of grommets: an unwanted sequel of grommet insertion
1Department of Otolaryngology, Royal Gwent Hospital, Newport, South Wales, UK. manoj.kumar@talk21.com
The Journal of Laryngology and Otology
|August 30, 2000
Abstract:
Grommet insertion is one of the commonest surgical procedures performed in the UK. We have come across three cases in which grommets have displaced medially in the middle ear after establishing a satisfactory post-insertion position. We suggest that an abnormally long myringotomy incision and improper placement of the grommet are responsible for this unwanted outcome.