Related Experiment Video
Updated: Jul 29, 2026

Assessing Changes in Volatile General Anesthetic Sensitivity of Mice after Local or Systemic Pharmacological Intervention
Published on: October 16, 2013
Kinetics and dynamics of lorazepam during and after continuous intravenous infusion
D J Greenblatt1, L L von Moltke, B L Ehrenberg
1Department of Pharmacology and Experimental Therapeutics, Tufts University School of Medicine, Boston, MA 02111, USA. dj.greenblatt@tufts.edu
Objective:
To evaluate the kinetics and dynamics of lorazepam during administration as a bolus plus an infusion, using electroencephalography as a pharmacodynamic end point.
Methods:
Nine volunteers received a 2-mg bolus loading dose of lorazepam, coincident with the start of a 2 microg/kg/hr zero-order infusion. The infusion was stopped after 4 hrs. Plasma lorazepam concentrations and electroencephalographic activity in the 13- to 30-Hz range were monitored for 24 hrs.
Results:
The bolus-plus-infusion scheme rapidly produced plasma lorazepam concentrations that were close to those predicted to be achieved at true steady state. Mean kinetic values for lorazepam were as follows: volume of distribution, 126 L; elimination half-life, 13.8 hrs; and clearance, 109 mL/min. Electroencephalographic effects were maximal 0.5 hr after the loading dose, were maintained essentially constant during infusion, and then declined in parallel with plasma concentrations after the infusion was terminated. There was no evidence of tolerance. Plots of pharmacodynamic electroencephalographic effect vs. plasma lorazepam concentration demonstrated counterclockwise hysteresis, consistent with an effect-site equilibration delay. This was incorporated into a kinetic-dynamic model in which hypothetical effect-site concentration was related to pharmacodynamic electroencephalographic effect via the sigmoid Emax model. The analysis yielded the following mean estimates: maximum electroencephalographic effect, 12.7% over baseline; 50% effective concentration, 13.1 ng/mL; and effect-site equilibration half-life, 8.8 mins.
Conclusion:
Despite the delay in effect onset, continuous infusion of lorazepam, preceded by a bolus loading dose, produces a relatively constant sedative effect on the central nervous system, which can be utilized in the context of critical care medicine.
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Nonlinear Pharmacokinetics: Drug Elimination for IV Bolus Injection
Following the administration of a single intravenous (IV) bolus injection, we can determine the concentration of the drug in the plasma at any given time. This calculation is achieved using a specific equation that integrates the values of Vmax and KM.
We can also...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations

